Welcome to www.cnctt.com official website!

Surface Roughness Tester with a Renishaw probe head and calibrated scales for aerospace first article inspection – measurement volume of 700 × 1000 × 600 mm

Surface Roughness Tester with a Renishaw probe head and calibrated scales for aerospace first article inspection – measurement volume of 700 × 1000 × 600 mm. a Renishaw probe head and calibrated scale

Get a Quote
Surface Roughness Tester with a Renishaw probe head and calibrated scales for aerospace first article inspection – measurement volume of 700 × 1000 × 600 mm
Surface Roughness Tester with a Renishaw probe head and calibrated scales for aerospace first article inspection – measurement volume of 700 × 1000 × 600 mm

Surface Roughness Tester with a Renishaw probe head and calibrated scales for aerospace first article inspection – measurement volume of 700 × 1000 × 600 mm

Surface Roughness Tester with a Renishaw probe head and calibrated scales for aerospace first article inspection – measurement volume of 700 × 1000 × 600 mm. a Renishaw probe head and calibrated scale

Contact Number: 18681062885
Product Details

Surface Roughness Tester with a Renishaw probe head and calibrated scales for aerospace first article inspection – measurement volume of 700 × 1000 × 600 mm

A Surface Roughness Tester is where a machining process proves itself: dimensions are checked against the drawing before parts leave the shop. The Surface Roughness Tester described here is built with a Renishaw probe head and calibrated scales and specified for aerospace first article inspection. metrology with calibrated equipment and documented uncertainty sits behind the numbers below, which are stated as delivered rather than as a best case.

The parts that matter most are the interfaces: bores, sealing faces, threads and mounting patterns. Those are held to measurement uncertainty 2–3 µm, verified against the drawing, and recorded before anything is packed.

Specification

ProcessMetrology with calibrated equipment and documented uncertainty
Material / configurationa Renishaw probe head and calibrated scales
Size / capacitymeasurement volume of 700 × 1000 × 600 mm
Tolerancemeasurement uncertainty 2–3 µm
Surface finishcalibrated and certified
Applicationsurface roughness tester for aerospace first article inspection
InspectionDimensional report, material certificate, first article report on request
Lead time7–15 working days for samples, 3–4 weeks for production
Minimum order1 piece for prototypes, from 50 pieces for production pricing

Surface Roughness Tester with a Renishaw probe head and calibrated scales for aerospace first article inspection – measurement volume of 700 × 1000 × 600 mm manufacturing detail

Manufacturing process

The operation sequence is decided before the first chip is cut: roughing to leave even stock, semi-finishing, then metrology with calibrated equipment and documented uncertainty as the final operation. That order is what keeps measurement uncertainty 2–3 µm stable as the batch runs and the machine warms up.

Material is purchased against a certificate and checked on receipt, so the composition is known before any cutting starts. Work in progress is identified by part number and operation, and the finished parts are deburred, cleaned and protected before they leave the machine area.

Typical applications

Most of the work supplied in this category falls into the following examples.

  • First article inspection reports.
  • Incoming goods verification.
  • Tool wear trend monitoring.
  • Capability studies on critical dimensions.
  • Reverse engineering of legacy parts.

Surface Roughness Tester with a Renishaw probe head and calibrated scales for aerospace first article inspection – measurement volume of 700 × 1000 × 600 mm finished parts

Quality control and documentation

Every batch is measured against the drawing with calibrated equipment, and results are recorded against the part number rather than kept on a scrap of paper.

Material certificates to EN 10204 3.1, dimensional reports and first article inspection reports are issued with the shipment where the application requires them. Calibration dates and measurement uncertainty are recorded alongside every result.

Ordering, lead time and packaging

Quotations are returned within one working day of a complete drawing package. Lead time is quoted from drawing approval, not from the date of enquiry.

Surface Roughness Tester with a Renishaw probe head and calibrated scales for aerospace first article inspection – measurement volume of 700 × 1000 × 600 mm inspection and packing

Frequently asked questions

How accurate is shop floor measurement?

A CMM in a controlled room gives uncertainty around 2 to 3 micrometres. On the machine, probing is accurate enough to detect drift, which is the reason to use it, rather than to replace the CMM.

What documentation comes with inspection?

A dimensional report listing every measured feature with nominal, actual and deviation, plus the equipment used, its calibration date and the environmental conditions.

How long does delivery take?

Sample parts are typically shipped in 7 to 15 working days after drawing approval. Production batches run 3 to 4 weeks depending on quantity, finishing and inspection requirements.

To discuss surface roughness tester requirements, send the model and the drawing with the quantities required. Feedback on manufacturability is given free of charge before any order is placed.